I have a 1kx1K 8 bit set of stacks of a 2 color Z series from a Leica Sp2. (so 2 25 frame z stacks, one green, one red).
I use Bio formats to import the files as a hyperstack in FIJI. Color one red, the other green. So far, so good.
Now I use Stack to RGB, but it gripes "A 2 or 3 image stack or hyperstack is required".
Is this a bug, or am I missing something? I have tried converting to stacks, stack concatenate..
Ethan.
Ethan Cohen, Ph.D.
Div of Biomedical Physics, WO62 Rm 1204
Office of Science and Engineering Labs,
FDA Center for Devices and Radiological Health
White Oak Federal Res Ctr.
10903 New Hampshire Ave.
Silver Spring, MD 20993
Web:
http://go.usa.gov/cegV3Office: 301-796-2485
Lab:301-796-2762
Fax: 301-796-9927
Cell: 301-538-7544
[cid:image001.png@01D1C57E.DFA022A0]<
http://www.fda.gov/>Excellent customer service is important to us. Please take a moment to provide feedback regarding the customer service you have received:
https://www.research.net/s/cdrhcustomerservice?O=700&D=740&B=740&E=&S=E"THIS MESSAGE FROM ETHAN COHEN IS INTENDED ONLY FOR THE USE OF THE PARTY TO WHOM IT IS ADDRESSED AND MAY CONTAIN INFORMATION THAT IS PRIVILEGED, CONFIDENTIAL, AND PROTECTED FROM DISCLOSURE UNDER LAW. If you are not the addressee, or a person authorized to deliver the document to the addressee, you are hereby notified that any review, disclosure, dissemination, copying, or other action based on the content of this communication is not authorized. If you have received this document in error, please immediately notify the sender immediately by e-mail or phone."