Re: Questions about analyze particles
Posted by
Wayne Rasband on
Nov 30, 2009; 12:52am
URL: http://imagej.273.s1.nabble.com/Questions-about-analyze-particles-tp3690273p3690275.html
On Nov 29, 2009, at 1:53 PM, Gabriel Landini wrote:
> Some more info on this issue.
> The summary columns are not aligned correctly, when one selects to
> output the Slice Position (because there is an extra column). If you
> do not do that, the table is OK.
The v1.43m4 daily build fixes a bug that could cause the Results table
to become scrambled when using Analyze>Summarize with "Stack Position"
enabled in Analyze>Set Measurements. Being able to take advantage of
bug fixes like this is one advantage of using the daily builds. The
daily builds also have new features, such as the image overlays (added
in 1.43k) required to use the new SIOX (Simple Interactive Object
Extraction) plugin (
http://rsb.info.nih.gov/ij/plugins/siox/).
-wayne