Re: Analysis of CT image
Posted by
Robert Martin-3 on
Nov 16, 2006; 8:18pm
URL: http://imagej.273.s1.nabble.com/Filters-Variance-tp3700988p3700992.html
Hi Nur,
I had a similar question awhile ago. What I did find that you could
do is 1) use the line tool and 2) change the line width tool
(edit>>Options>>LIne width). Then you can find the profile of a
widthed line to your choicing. (Cntl-K for doing the profile).
Good Lunk
Robert Martin
Carleton University
On Nov 16, 2006, at 5:17 AM, M. Nur Heriawan wrote:
> Dear list,
>
> I am a new user of ImageJ. I would like to use ImageJ
> to analyze the sequence of images resulted from X-ray
> CT scanner.
>
> My question: Is it possible to draw the profile of CT
> value or attenuation coefficient instead of (just)
> grayscale value using ImageJ? Are there any plugins
> available to address this purpose?
>
> Thank you very much for kind attention.
>
> Best regards,
>
>
> ---------------
> M. Nur Heriawan
> Lab. of Applied Geosciences & Tech.
> Kumamoto Univ., Japan
>
>
>
> ______________________________________________________________________
> ______________
> Sponsored Link
>
> Mortgage rates near 39yr lows.
> $420k for $1,399/mo. Calculate new payment!
> www.LowerMyBills.com/lre