Login  Register

Re: particle analysis in bubble motion experiments

Posted by Jerome Mutterer-3 on Oct 14, 2014; 1:00pm
URL: http://imagej.273.s1.nabble.com/particle-analysis-in-bubble-motion-experiments-tp5010029p5010030.html

Dear Marcel,
You should add the "Bounding Rectangle" measurement to the list of measured
parameters under Analyze>Set Measurements...
BY will be the top of an object, and BY+Height will give you the bottom
coordinate.
For your X coordinate, you could use BX+(Width/2)
Sincerely,
Jerome.

On 14 October 2014 14:44, Marcel Krzan <[hidden email]> wrote:

> Dear Friends,
>
> I use the ImageJ Macros in my reseach work. I already prepared few Macros,
> which analysed the bubble motion in various surfacxtant solution.
>
> Till now I used the particle analysis function and analysed the moving of
> center of the mass. However now in my experiments I have a strong pulsation
> of the bubble shape which influenced the values of the bubble local
> velocities.
>
> Therefore I need to find the coordinates (X,Y) of the points on the bubble
> TOP and BOTTOM
>
> Can you help me? In which way could I modify the Particle analysis function
> to obtain those data.
>
> Regards
> Marcel Krzan
>
> --
> ImageJ mailing list: http://imagej.nih.gov/ij/list.html
>



--
Jerome Mutterer
CNRS - Institut de biologie moléculaire des plantes
12, rue du Général Zimmer
67084 Strasbourg Cedex
T 0367155339
www.ibmp.cnrs.fr

--
ImageJ mailing list: http://imagej.nih.gov/ij/list.html