Re: Display image using calibrated values

Posted by Michael Schmid on Nov 14, 2014; 11:21am
URL: http://imagej.273.s1.nabble.com/Display-image-using-calibrated-values-tp5010444p5010445.html

Hi David,

convert your image to 32-bit (float), the it forgets the original pixel data and only uses the calibrated values. Then set a display range of your choice in the Brightness&Contrast panel.

Michael
________________________________________________________________
On Nov 14, 2014, at 12:17, Dawid Krzempek wrote:

> Hello,
> Hi all,
> I have another problem. It's about display calibrated image.
> Is there any possibility to display image using calibrated nor signal
> values?
> For example if my calibration function is:
> f(signal)=0
> I would like to see the all black image. By default I can see my image in
> signal values.
> Calibrated values I can see only in profiles and measurement.
>
> My goal is to make the map of image in calibrated values using Jet LUT.
> Best regards
> Dawid

--
ImageJ mailing list: http://imagej.nih.gov/ij/list.html