Particle analyzer summary table

Sebastien
Hi,

ImageJ version: updated Fiji, OS: windows 7 enterprise 64.

The summary table is always appearing when analyzing particles even when disabled from the dialog box. This is not observed on other machines with the same Fiji version. Anybody experiencing this as well? Any idea on how to fix it?

Seb

--
ImageJ mailing list: http://imagej.nih.gov/ij/list.html
Reply | Threaded
Open this post in threaded view
|

Re: Particle analyzer summary table

Rainer M. Engel
Am 27.02.2013 12:51, schrieb Sébastien Tosi:
> The summary table is always appearing when analyzing particles even when disabled from the dialog box.


Hey Sébastien,

I'm only guessing, but on my Win7 x64 it works as expected.

possible Causes (guesses):
- Aero or other Graphics enhanced UI active
- Java Version ?
- graphics driver ?

Maybe in that order.. If not, I'm not sure what could it be.

HTH,
Rainer


--
Rainer M. Engel, Dipl. Digital Artist
scientific|Media GbR
Pichelsdorfer Str. 143
13595 Berlin

--
ImageJ mailing list: http://imagej.nih.gov/ij/list.html
Reply | Threaded
Open this post in threaded view
|

Re: Particle analyzer summary table

Michael Schmid
In reply to this post by Sebastien
Hi Sebastien,

this looks like a remanent form a very old ImageJ version in the
preferences file IJ_prefs.txt. It may be caused by bit 1 in the ap.options
of the prefs file being set).
If you have a reasonably recent version of ImageJ (1.46q and up),
IJ_prefs.txt should be in a folder named the home directory in a folder
named ".imagej" (possibly hidden?). Otherwise, it might be in the ImageJ
directory.
Open the file with a text editor and search for the line with
"ap.options=". Set the number there to 0, save it. Then open ImageJ and
set your favorite measurement options again (Analyze>Set measurements and
the various checkboxes of Analyze particles).

The problem might be also caused by an IJ_prefs.txt file with no write
access for the user (ImageJ version <1.46q). Upgrade ImageJ to have this
file in a user-writable directory.

Michael
------------------------------------------------------------------


On Wed, February 27, 2013 12:51, Sébastien Tosi wrote:

> Hi,
>
> ImageJ version: updated Fiji, OS: windows 7 enterprise 64.
>
> The summary table is always appearing when analyzing particles even when
> disabled from the dialog box. This is not observed on other machines with
> the same Fiji version. Anybody experiencing this as well? Any idea on how
> to fix it?
>
> Seb
>
> --
> ImageJ mailing list: http://imagej.nih.gov/ij/list.html
>

--
ImageJ mailing list: http://imagej.nih.gov/ij/list.html