Hi Niklas,
> Now I can progress in importing these DICOM files (file/import/bio
> formats) the only problem is that it seems to open only the first three
> frames (or the first frame in three different manners).
It may be a bug in the Bio-Formats DICOM reader. Would you be willing to
submit a sample DICOM file that exhibits the problem? You can use the Help
> Upload Sample Image command in the Fiji ImageJ distribution (
http://fiji.sc/). Or if the file is very large, let me know and I'll send
you our SFTP server information off-list.
Regards,
Curtis
On Tue, Jul 10, 2012 at 9:41 AM, Niklas König <
[hidden email]>wrote:
> Hey,
>
> I am currently trying to analyse large DICOM clips (200MB) which I
> collected with a ultrasound machine (here they are called Cine loop).
> In order to import the DICOM files I am using the LOCI plugin which was
> successful for simple (and smaller) ultrasound pictures.
>
> After increasing ImageJ's (32-bit) memory to 500MB I got rid of the "Out
> of memory" message that I got when I first tried to open these clips.
> Now I can progress in importing these DICOM files (file/import/bio
> formats) the only problem is that it seems to open only the first three
> frames (or the first frame in three different manners). The command line is
> as follows:
> 1/3 (c:1/3 - Series 0)
>
> Has anybody experienced similar problems or is familiar with opening these
> kinds of files?
> I am most thankful for any idea that could help here.
> Thank you very much!
> Regards,
>
> Niklas
>
> --
> ImageJ mailing list:
http://imagej.nih.gov/ij/list.**html<
http://imagej.nih.gov/ij/list.html>
>
--
ImageJ mailing list:
http://imagej.nih.gov/ij/list.html